Fixed Wire Testing

At Powertest we can help you with your Fixed Wire and Mains Testing in Haywards Heath and throughout West Sussex.

Why you need Fixed Wire testing at your premises?

Electrical installations, like all infrastructure components, deteriorate and sustain damage in everyday service. Conduits, cabling, seals, sockets and switches are all susceptible to impact damage and wear and tear. Wiring can be disturbed and contacts become loose due to unexpected mechanical strains.

Depending on the environment in which you work, corrosive liquids or hazardous conditions can accelerate the deterioration of both conductors and insulators, or cause wiring to oxidise and deteriorate faster than normal. To minimise risks and ensure your wiring complies with all relevant regulations and legal obligations, Powertest provides comprehensive Fixed Wire Testing to IET Wiring Regulations BS7671:2008 Incorporating Amendment No.1:2011 Across the United Kingdom.

 
How often should your establishment be inspected and tested?

The Institution of Engineering and technology formerly the (IEE) give guidance for the “recommended” frequencies for the inspection & test of most electrical installations, with 3 & 5 years recommended for most commercial & industrial type premises.

However, consideration will need to be given to other factors that may require a more frequent testing regime. A careful assessment of your installation and its use should be conducted to help determine this frequency.

We at Powertest offer a site survey before work is undertaken to access the magnitude of the site and to set up a site plan for further visits. We offer a range of ways to complete the testing in the given timescale.

BS7671 intervals between periodic inspections or fixed wire testing

Installation Max. period between inspections
Domestic premises 10 years or change of occupier
Commercial premises 5 years or change of occupier
Educational establishments 5 years
Hospitals 5 years
Industrial premises 3 years
Cinemas 1 year
Churches 5 years
Leisure complexes 1 year
Places of public entertainment 1 year
Theatres, etc. 1 year
Agricultural and horticultural 3 years
Caravans 3 years
Caravan sites 3 years
Emergency lighting 3 years
Fire alarm systems 1 year
Launderettes 1 year
Petrol filling stations 1 year
Public houses 5 years
Marinas 1 year
Highway power supplies 6 years

 
What Powertest offers

  • Fully Qualified 17th edition electricians (including Amendment No1:2011).
  • NICEIC & ISO 9001 approved company.
  • Highest quality of customer/client service.
  • Professional, punctual and tidy.
  • Work to your needs with minimal disruption to your workforce.
  • Extremely competitive pricing.
  • All reports stored securely online for easy viewing.

 
What type of tests we may need to carry out during our visit?

During the Testing process a variety of testing equipment and procedures are employed to determine the current condition of the installation. Each test performed has a specific role during the testing process.

Bonding conductors continuity, ring circuit continuity, insulation resistance, polarity, earth electrode resistance, earth fault loop impedance, functional tests of RCDs, functional tests of circuit breakers, isolators and switching devices. All using calibrated IEE recommended equipment, to ISO 17025 by a UKAS accredited calibration house.